The growing need for energy in all dimensions, especially in residential and office use, has made the need to use renewable energy sources a vital issue. It is generally assumed that Light Shelf is a useful tool for daylight utilization. Therefore, most green buildings benefit from this technology without a realistic assessment. The purpose of this study is to objectively investigate the ability of Light Shelf to improve daylight as well as visual comfort by experimental research in Guilan. In this experimental study, the Scale Model on 1:5 scale was built and investigated the effects of a Light Shelf system that uses different illumination (light intensity) interiors with outside amount of light while resizing the interior and exterior Light Shelf size. The data were analyzed statistically and the performance of Light Shelf in different ways was analyzed. The results show that in 73% times, the Light Shelf can increase daylight in the depth. Contrary to the notion that the use of optical light could reduce the intensity of light and subsequently reduce grey near the window, it was found that the use of this system could only 43% reduce the intensity of light and grey near the window.

Keywords


[3] V.G. Hansen, Innovative Daylighting Systems for Deep-Plan Commercial Buildings, Queensland University of Technology CW. PP 1.1-1.14, 2.1-2.17, 3.21-3.48, 2006.
[4] L. Heangwoo et al., Effectiveness of a perforated light shelf for energy saving', Energy and Buildings, 2017.
[5]  Hunt, D.R., Predicting artificial lighting use – a method based upon observed patterns of behavior. Light. Res. Technol., 1980.
[6] M.H. Moazzeni, Z. Ghiabaklou, Investigating the Influence of Light Shelf Geometry Parameters on Daylight Performance and Visual Comfort, a Case Study of Educational Space in Tehran, Iran, Buildings, 2016.
[7] A. Warrier, B. Raphael. Performance evaluation of light shelves, Energy and Buildings, 2017.
 [8] A. Meresi, Evaluating daylight performance of light shelves combined with external blinds in south-facing classrooms in Athens, Greece', Energy and Buildings, 2016.
[9] A.A. Freewan, L. Shao, and S. Riffat, Optimizing performance of the lightshelf by modifying ceiling geometry in highly luminous climates, Solar Energy, 2008
[10] M. Roshan, et al., Empirical validation of daylight simulation tool for a test office with anidolic daylighting system. Journal of Basic and Applied Scientific Research, 3(9), 104-112.,2013
[11]  M. Roshan, A.S. Barau, Assessing Anidolic Daylighting System for efficient daylight in open plan office in the tropics, Journal of Building Engineering 8, 58-69, 2016.
[14]  M. Ghasemi, M. Roshan, The influence of well geometry on the daylight performance of atrium adjoining spaces: A parametric study, Journal of Building Engineering 3, 39-47, 2015.