Methods of calculating the rate of air infiltration into the building for the use of HVAC and building energy calculations

Document Type : Review Article

Authors

1 Department of Mechanical Engineering. Tarbiat Modares University, Tehran, Iran

2 Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran.

3 Energy & Environmental Design, Building and Housing Research Center, Tehran, Iran.

Abstract

The uncontrolled flow of air from outside into the building through cracks and pores of the building happens, say air infiltration. Air infiltration into the building in several viewpoints, such as energy consumption, HVAC systems design, thermal comfort, indoor air quality and pollution and humidity is very important. According to many studies that have been conducted, air infiltration the reason 15 to 30 percent of and energy consumption and the heat load of the building, indicating the necessity of research on the subject. In general, three operating wind pressure, stack effect and HVAC systems has caused air infiltration in buildings, the impact of all three factors must be considered in the calculations. From the viewpoint of HVAC, the main issue is how to calculate the rate of air infiltration in the building. Heretofore several related analytical and experimental and standard tests for air infiltration rate of the different components of the building are presented. In this paper, some of the relations and equations presented in this issue have been studied. Finally the power low equation because of the accuracy and more applied to recent research, for calculating the rate of air infiltration in buildings is recommended.

Keywords


[1] ASHRAE. Handbook of fundamentals. Chapter 16: ventilation and infiltration. USA Society of Heating, Refrigeration and Air-Conditioning Engineers, 2009.
[2] K. Hassouneh, A. Alshboul, and A. Al-Salaymeh, Influence of infiltration on the energy losses in residential buildings in Amman, Sustainable Cities and Society, Vol. 5, pp. 2-7, 2012.
[3] G. Han, J. Srebric, and E. Enache-Pommer, Different modeling strategies of infiltration rates for an office building to improve accuracy of building energy simulations, Energy and Buildings, 86, 2015, pp. 288-295.
[4] J. Jokisalo, et al., Building leakage, infiltration, and energy performance analyses for Finnish detached houses, Building and Environment, Vol. 44, pp. 377-387, 2009.
[5] C. Younes, C.A. Shdid, and G. Bitsuamlak, Air infiltration through building envelopes: A review, Journal of Building physics, Vol. 35, pp. 267-302, 2012.
[8] S.B. Sadineni, S. Madala, and R.F. Boehm, Passive building energy savings: A review of building envelope components, Renewable and Sustainable Energy Reviews, Vol. 15, pp. 3617-3631, 2011.
[9] C. Chen, et al., A methodology for predicting particle penetration factor through cracks of windows and doors for actual engineering application, Building and Environment, Vol. 47, pp. 339-348, 2012.
[10] T. O. Relander, J.V. Thue, and A. Gustavsen, Air tightness performance of different sealing methods for windows in wood-frame buildings, 8th Nordic Symposium on Building Physics, Copenhagen, Denmark, 2008.
[11] T. O. Relander, J.V. Thue, and A. Gustavsen, The influence of different sealing methods of window and door joints on the total air leakage of wood-frame buildings, Proceedings of the Nordic Symposium on Building Physics, Copenhagen, Denmark, 2008.
[12] A. Sfakianaki, et al., Air tightness measurements of residential houses in Athens, Greece, Building and Environment, Vol. 43, pp. 398-405, 2008
[13] M. I. Montoya, et al., Air leakage in Catalan dwellings: developing an airtightness model and leakage airflow predictions, Building and Environment, Vol. 45, pp. 1458-1469, 2010.
[14] J. Straube. Air Flow Control in Buildings, Accessed 2 September 2015; http://www.http://buildingscience.com.
[16] ASHRAE, Handbook of fundamentals, Chapter 27: ventilation and infiltration. USA Society of Heating, Refrigeration and Air-Conditioning Engineers, 2005.
[17] N. Van Den Bossche, A. Janssens, and J. Moens, Watertightness of window frames: experience of notified bodies, 4th International Building Physics Conference (IBPC), Istanbul Technical University, 2009.
[18] G. Finch, J. Straube, and C. Genge, Air leakage within multi-unit residential buildings–Testing and implications for building performance, Proceedings of the 12th Canadian conference on building science and technology, 2009.
[19] G. N. Walton, A computer algorithm for predicting infiltration and interroom airflows, ASHRAE Trans; (United States), 1984. 
[20] T. Qi, Z. ONeill, and G.L. Augenbroe, Inverse modeling to estimate the effective leakage area in buildings, 2014.
[21] M. H. Sherman and W.R. Chan, Building air tightness: research and practice, Building Ventilation: the state of the Art, pp. 137-162, 2006.
[22] I. S. Walker, D.J. Wilson, and M.H. Sherman, A comparison of the power law to quadratic formulations for air infiltration calculations, Energy and Buildings, Vol. 27, pp. 293-299, 1998.
[23] ASTM E283-91, Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen, ASTM International, West Conshohocken, PA, 1999.
[25] M. H. Kim, J.-H. Jo, and J.-W. Jeong, Feasibility of building envelope air leakage measurement using combination of air-handler and blower door. Energy and Buildings, Vol. 62, pp. 436-441, 2013.