Abstract
According to the official statistics of the International Energy Agency, about forty percent of the world’s energy is consumed by buildings. Considering the energy crisis and the destructive effects on the environment and humans, finding new solutions and ideas in energy consumption is the duty of today’s architects. To save energy for the proper use of useful daylight and ventilation, the implementation of passive solutions to regulate the indoor environment and on the other hand daylight plays a significant role in ensuring the health of residents. Therefore, by examining the available resources in the field of energy consumption reduction and extracting the indicators and systems used in them, the simulation method with the Ladybug tools v1.6 plugin on the Grasshopper software platform was selected. By optimizing the ratio of window to wall area (WWR), the results of two factors of useful day lighting and building ventilation were improved. 100 generations were produced in the optimization process. The optimal solution has been produced among the generations that the optimal ratio of WWR for useful daylight is set at 40% on the north face and 20% on the south face, and 15% on the north face and 40% on the south face for the ventilation and energy sector of the building.

Keywords

Subjects

- مراجع
[1] World Energy Council, World Energy Resources: An Overview, London, UK, 2012. [Online]. Available: https://www.worldenergy.org/assets/downloads/World-Energy-Resources-2012-Overview-Report.pdf
[2] A. H. Ostadzad, Solar energy and sustainable economic development in Iran, Journal of Renewable and New Energy, Vol. 11, No. 2, pp. 128–137, 2024. (in Persian)
[3] Z. Soltaninejad, M. Ghasemi, and M. Soltaninejad, Technical and environmental analysis of using a photovoltaic-thermal system to provide heating energy for a school building in Kerman, Journal of Renewable and New Energy, Vol. 11, No. 1, pp. 50–59, 2024. (in Persian)
[4] O. Rahaei, and A. Roasaei, Studying the Separating Walls Function in Administrative Spaces on Quality of Air Conditioning and Indoor Airflow Using CFD Method, Journal of Architecture and Urban Planning, Vol. 10, No. 19, pp. 61–76, 2017. (in Persian)
[5]  J. A. Jakubiec, and C. F. Reinhart, Predicting visual comfort conditions in a large daylit space based on long-term occupant evaluations: A field study, in Proceedings of the 13th International Building Performance Simulation Association Conference (IBPSA), Chambéry, France, Aug. 26–28, 2013.
[6] M. B. C. Aries, M. P. J. Aarts, and J. van Hoof, Daylight and health: A review of the evidence and consequences for the built environment, Lighting Research & Technology, Vol. 47, No. 1, pp. 6-27, 2013.
[7]  N. Jamala, A. N. Wika, and A. Kusno, Analysis of Daylight Distribution on Building Height and Space Depth, in IOP Conference Series: Materials Science and Engineering, Vol. 619, No. 1, 012044, 2019.
[8] T. Srisamranrungruang, and K. Hiyama, Balancing of natural ventilation, daylight, thermal effect for a building with double-skin perforated facade (DSPF), Energy and Buildings, Vol. 210, 109765, 2020.
[9] X. Chen, and H. Yang, Combined thermal and daylight analysis of a typical public rental housing development to fulfil green building guidance in Hong Kong, Energy and Buildings, Vol. 108, pp. 420–432, 2015.
[10] E. Sorooshnia, P. Rahnamayiezekavat, M. Rashidi, M. Sadeghi, and B. Samali, Curve Optimization for the Anidolic Daylight System Counterbalancing Energy Saving, Indoor Visual and Thermal Comfort for Sydney Dwellings, Energies, Vol. 16, No. 3, 1090, 2023.
[11] A. S. Ebrahimpour and B. Mohammad Kari, A new method to designing window based on energy consumption, Modares Mechanical Engineering, Vol. 11, No. 1, pp. 77–88, 2011. (in Persian)
[12] L. I. Wong, A review of daylighting design and implementation in buildings, Renewable and Sustainable Energy Reviews, Vol. 74, pp. 959–968, 2017.
[13] S. Mohammadzadeh, S. A. Yazdanfar, and S. Norouzian-Maleki, Quantitative and qualitative efficiency of daylight using optical Fiber lighting systems in Housing, Journal of Renewable and New Energy, Vol. 9, No. 2, pp. 57-68, 2022. (in Persian)
[14] S. Cesari, P. Valdiserri, M. Coccagna, and S. Mazzacane, The energy saving potential of wide windows in hospital patient rooms, optimizing the type of glazing and lighting control strategy under different climatic conditions, Energies, Vol. 13, No. 8, 2116, 2020.
[15] R. Liang, Y. Sun, M. Aburas, R. Wilson, and Y. Wu, Evaluation of the thermal and optical performance of thermochromic windows for office buildings in China, Energy and Buildings, Vol. 176, pp. 216–231, 2018.
[16] R. Fayaz, Optimum Window Area for Residential Buildings in Ardabil and Tehran, Journal of Architecture and Urban Planning, Vol. 5, No. 10, pp. 105–119, 2013. (in Persian)
[17] A. Razmi, M. Rahbar, and M. Bemanian, PCA-ANN integrated NSGA-III framework for dormitory building design optimization: Energy efficiency, daylight, and thermal comfort, Applied Energy, Vol. 305, 117828, 2022.
[18] H. Sabry, A. Sherif, M. Gadelhak, and M. Aly, Balancing the daylighting and energy performance of solar screens in residential desert buildings: Examination of screen axial rotation and opening aspect ratio, Solar Energy, Vol. 103, pp.364–377, 2014.
[19] M. Thalfeldt, E. Pikas, J. Kurnitski, and H. Voll, Facade design principles for nearly zero energy buildings in a cold climate, Energy and Buildings, Vol. 67, pp. 309–321, 2013.
[20] H. Ghadamian, S. H. Mousavi, and A. R. Ghadi, Analytical solution for energy modeling of double skin façades building, Energy and Buildings, Vol. 49, pp. 251–260, 2012.
[21] F. Hammad and B. Abu-Hijleh, The energy savings potential of using dynamic external louvers in an office building, Energy and Buildings, Vol. 42, No. 10, pp. 1888–1895, 2010.
[22] J. Gagne and M. Andersen, A generative facade design method based on daylighting performance goals, Energy and Buildings, Vol. 5, No. 3, pp. 189-204, 2012
[23] O. C. Dewi, K. Rahmasari, T. A. Hanjani, A. D. Ismoyo, and A. M. Dugar, Window-to-Wall Ratio as a Mode of Daylight Optimization for an Educational Building with Opaque Double-Skin Façade, Journal of Sustainable Architecture and Civil Engineering, Vol. 30, No. 1, pp. 32–43, 2022.
[24] S. Sayadi, A. Hayati, and M. Salmanzadeh, Optimization of Window‑to‑Wall Ratio for Buildings Located in Different Climates: An IDA‑Indoor Climate and Energy Simulation Study, Energies, Vol. 14, 1974, 2021.
[25] D. H. W. Li and S. L. Wong, Daylighting and energy implications due to shading effects from nearby buildings, Applied Energy, Vol. 84, No. 12, pp. 1199–1209, 2007.
[26] L. Karlsen, P. Heiselberg, and I. Bryn, Occupant satisfaction with two blind control strategies: Slats closed and slats in cut-off position, Solar. Energy, Vol. 115, pp. 166–179, 2015.
[27] M. N. Bahadori, A. R. Dehghani-sanij, and A. Sayigh, Wind Towers: Architecture, Climate and Sustainability, Switzerland: Springer Cham, 2014.
[28] M. Mohammadi, Z. Ghiabaklou, and H. Moztarzadeh, Determining the optimal dimensions and opening area for windows in residential buildings in the hot-humid climate of Asalouyeh city, Journal of Fine Arts: Architecture and Urban Planning, Vol. 28, No. 3, pp. 91–105, 2023. (in Persian)
[29] S. Bagheri, H. Moradinasab, and M. Yeganeh, The effect of window proportions in low‑rise residential buildings on annual energy consumption in humid temperate climate (case study: Rasht city in Iran), Frontiers in Energy Research, 12:1463678, 2024.
[30] Ventilation for Acceptable Indoor Air Quality, ASHRAE Standard 62.1, 2022.
[31] Y. C. Chan and A. Tzempelikos, Efficient venetian blind control strategies considering daylight utilization and glare protection, Solar Energy, Vol. 98, Part C, pp. 241-254, 2013.
[32] S. Farivar and S. Teimourtash, Impact of window design on dynamic daylight performance in an office building in Iran, Journal of Daylighting, Vol. 10, No. 1, pp. 31-44, 2023.
[33] O. Humaidan, Khaled Almazam, F. M. Bashir, M. J. Alshayeb, Nedhal Al-Tamimi, and Yakubu Aminu Dodo, Comprehensive assessment of dynamic shading devices for daylighting and energy management in Saudi Arabian hot-arid buildings, Energy and Buildings, Vol. 346, 116180, 2025.
[34] Y. Jiang, Z. Qi, S. Ran, and Q. Ma, A Study on the Effect of Dynamic Photovoltaic Shading Devices on Energy Consumption and Daylighting of an Office Building, Buildings, Vol. 14, No. 3, 596, 2024.
[35] I. Acosta, M. Á. Campano, S. Domínguez-Amarillo, and J. Navarro Casas, Continuous Overcast Daylight Autonomy (DAo.con): A New Dynamic Metric for Sensor-Less Lighting Smart Controls, LEUKOS, Vol. 19, No. 4, pp. 343-367, 2023.
[36] T. Kristiansen, F. Jamil, I. A. Hameed, and M. Hamdy, Predicting annual illuminance and operative temperature in residential buildings using artificial neural networks, Building and Environment, Vol. 217, 109031, 2022.
[37] A. Kansal, and E. Rajasekar, A review on reduced order models for building and urban energy simulations, Journal of Building Performance Simulation, Vol. 18, No. 4, pp. 500-522, 2025.
[38] R. M. López-Lovillo, S. Domínguez-Amarillo, J. J. Sendra, and I. Acosta, How can a daylighting and user-oriented control system be configured? A state-of-the-art critical review, Journal of Building Engineering, Vol. 64, 105704, 2023.

  • Receive Date 19 April 2025
  • Revise Date 14 November 2025
  • Accept Date 10 December 2025