<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Iranian Society of Heating, Refrigerating, and Air Conditioning Engineers (IRSHRAE)</PublisherName>
				<JournalTitle>Journal of Renewable and New Energy</JournalTitle>
				<Issn>2423-4931</Issn>
				<Volume></Volume>
				<Issue>Articles in Press</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>09</Month>
					<Day>19</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Design and Construction of Optimized Light Tube for Application in High-Density Buildings</ArticleTitle>
<VernacularTitle>Design and Construction of Optimized Light Tube for Application in High-Density Buildings</VernacularTitle>
			<FirstPage></FirstPage>
			<LastPage></LastPage>
			<ELocationID EIdType="pii">253287</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyedeh Zahra</FirstName>
					<LastName>Yousefi</LastName>
<Affiliation>Department of Art and Architecture, University of Mazandaran, Babolsar, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Saeed</FirstName>
					<LastName>Mirzanejhad</LastName>
<Affiliation>Department of Atomic and Molecular Physics, University of Mazandaran, Babolsar, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-0717-819X</Identifier>

</Author>
<Author>
					<FirstName>Seyed Ali</FirstName>
					<LastName>Seyedian</LastName>
<Affiliation>Department of Art and Architecture, University of Mazandaran, Babolsar, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hesam</FirstName>
					<LastName>Nadalian</LastName>
<Affiliation>Department of Information Technology, Science and Research Branch, Islamic Azad University, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>07</Month>
					<Day>04</Day>
				</PubDate>
			</History>
		    <Abstract>The utilization of natural light in buildings plays a vital role in enhancing the quality of life for occupants and reducing energy consumption. A light tube, as an innovative daylight transmission technology, enables the transfer of sunlight from roofs or side walls into interior spaces. This study aims to apply this technology in high-density residential complexes through the design, fabrication, and performance evaluation of various light tube prototypes. Tubes with different dimensions and reflective materials were constructed, and their transmission efficiency was assessed under two conditions: in a laboratory setting with artificial light and in outdoor environments with natural sunlight. The results demonstrated that the tube dimension and quality of reflective material significantly influence the amount of transmitted light, and the integration of a collector at the tube entrance markedly improves system efficiency. The main innovation of this research is the proposal of incorporating smart louvered mirrors (multi-segment) with adjustable tilt and azimuth angles throughout the day (in spite of parabolic mirror) for light tubes. This strategy can substantially increase light transmission efficiency and provide an effective solution for improving daylighting quality and reducing energy consumption in sustainable architecture.</Abstract>
			<OtherAbstract Language="FA">The utilization of natural light in buildings plays a vital role in enhancing the quality of life for occupants and reducing energy consumption. A light tube, as an innovative daylight transmission technology, enables the transfer of sunlight from roofs or side walls into interior spaces. This study aims to apply this technology in high-density residential complexes through the design, fabrication, and performance evaluation of various light tube prototypes. Tubes with different dimensions and reflective materials were constructed, and their transmission efficiency was assessed under two conditions: in a laboratory setting with artificial light and in outdoor environments with natural sunlight. The results demonstrated that the tube dimension and quality of reflective material significantly influence the amount of transmitted light, and the integration of a collector at the tube entrance markedly improves system efficiency. The main innovation of this research is the proposal of incorporating smart louvered mirrors (multi-segment) with adjustable tilt and azimuth angles throughout the day (in spite of parabolic mirror) for light tubes. This strategy can substantially increase light transmission efficiency and provide an effective solution for improving daylighting quality and reducing energy consumption in sustainable architecture.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Natural illumination</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Light tube</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Effective transmission length</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">High-density buildings</Param>
			</Object>
		</ObjectList>
</Article>
</ArticleSet>
