<ArticleTitle>Investigating the effect of phase change material in Trombe wall on the energy efficiency of the building (Study case: Building of Tejarat Bank Shabea, University of Zanjan - cold and dry climate)</ArticleTitle>
<VernacularTitle>بررسی تاثیر مواد تغییر فاز دهنده دردیوار ترومب بر میزان بهره‌وری انرژی ساختمان (مورد پژوهی: ساختمان بانک تجارت شبعه دانشگاه زنجان- اقلیم سرد و خشک)</VernacularTitle>
			<FirstPage>46</FirstPage>
			<LastPage>52</LastPage>
			<ELocationID EIdType="pii">233278</ELocationID>
			
<ELocationID EIdType="doi">10.22034/jrenew.2026.233278</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مهرداد</FirstName>
					<LastName>بغدادی</LastName>
<Affiliation>کارشناسی ارشد، گروه معماری، دانشکده معماری و شهرسازی، دانشگاه بین المللی امام خمینی (ره)، قزوین، ایران</Affiliation>
<Identifier Source="ORCID">0009-0003-3165-2116</Identifier>

</Author>
<Author>
					<FirstName>حسین</FirstName>
					<LastName>مدی</LastName>
<Affiliation>استادیار، گروه معماری، دانشکده معماری و شهرسازی، دانشگاه بین المللی امام خمینی (ره)، قزوین، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-5537-593X</Identifier>

</Author>
<Author>
					<FirstName>مریم</FirstName>
					<LastName>آزموده</LastName>
<Affiliation>استادیار گروه معماری، دانشکده معماری و شهرسازی، دانشگاه بین المللی امام خمینی، قزوین، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-1719-8565</Identifier>

</Author>
<Author>
					<FirstName>نجمه</FirstName>
					<LastName>ماستری فراهانی</LastName>
<Affiliation>مربی،گروه معماری و شهرسازی، دانشگاه فنی و حرفه‌ای، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0003-4569-0423</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>05</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		<Abstract>Today, the use of solar energy is one of the ways to reduce the energy consumption of buildings. One of the practical methods in this field is the use of Trombe walls. The purpose of this research is to determine the solution to improve the thermal performance of Trombe wall, the thermal comfort of the interior of the building and reduce the cooling and heating load in all seasons, using phase change materials. The method of carrying out this quasi-experimental research using the simulation of a real project, in the Design Builder software environment, on two types of traditional trombe walls and with phase change materials, has been a real example in a cold and dry climate. From the investigations, it can be seen that a 30 cm thick concrete wall with a thermal resistance of 0.65 with a delay time of 7 hours and 12 minutes is the best type of traditional trombe wall; which reduces the consumption of heating, cooling and primary energy by about 20, 14 and 8 percent, respectively. In the combined Trombe wall, the amount of heating, cooling and primary energy can be reduced by 51, 11 and 15%, respectively, with phase change materials. This result points to the high efficiency of phase change materials in the thrombus wall in reducing the heating load. The use of phase change materials can improve the thermal comfort of the interior of the building and reduce energy consumption compared to the traditional trombe wall all year round.</Abstract>
			<OtherAbstract Language="FA">امروزه استفاده از انرژی خورشید، یکی از راهکارهای کاهش مصرف انرژی ساختمان‌ها است. از شیوه‌های کاربردی در این زمینه، استفاده از دیوارهای ترومب است. هدف از انجام این پژوهش تعیین راهکار بهبود عملکرد حرارتی دیوار ترومب، آسایش حرارتی فضای داخلی ساختمان و کاهش بار سرمایش و گرمایش در تمام فصول، با استفاده از مواد تغییر فاز دهنده است. روش انجام این پژوهش شبه تجربی با استفاده از شبیه‌سازی یک پروژه واقعی، در محیط نرم افزار دیزاین بیلدر، بر روی دو نوع دیوار ترومب سنتی و با مواد تغییر فاز دهنده، یک نمونه واقعی در اقلیم سرد وخشک بوده است. از بررسی‌های صورت گرفته می‌توان دریافت که دیوار بتنی به ضخامت 3۰ سانتی متر با مقاومت حرارتی 65/۰ با زمان تاخیر 7 ساعت و 12 دقیقه، بهترین نوع دیوار ترومب سنتی است؛ که مصرف گرمایش، سرمایش و انرژی اولیه را به ترتیب به میزان حدود 2۰، 14 و 8 درصد کاهش می‌دهد. در دیوار ترومب ترکیبی، با مواد تغییر فاز دهنده می‌توان میزان گرمایش، سرمایش و انرژی اولیه را به ترتیب 51، 11 و 15 درصد کاهش داد. این نتیجه به کارایی بالای مواد تغییرفازدهنده در دیوار ترومب در کاهش بار گرمایشی اشاره دارد. استفاده از مواد تغییر فاز دهنده می‌تواند آسایش حرارتی فضای داخلی ساختمان را بهبود می‌بخشد و مصرف انرژی را در مقایسه با دیوار ترومب سنتی در تمام سال کاهش می‌دهد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">دیوار ترومب</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تغییر فاز دهنده</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سرد و خشک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">بهره وری انرژی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jrenew.ir/article_233278_82cd7a6dcf53d45ef8cd5b99dc6a2ba8.pdf</ArchiveCopySource>
</Article>
</ArticleSet>