<ArticleTitle>Evaluation of double skin façade application to reduce energy consumption in cold and dry climate  (Case study: A commercial building in Karaj City)</ArticleTitle>
<VernacularTitle>ارزیابی بهره گیری از نمای دوپوسته به منظور کاهش مصرف انرژی در اقلیم سرد و خشک (نمونه موردی ساختمان تجاری در شهر کرج)</VernacularTitle>
			<FirstPage>72</FirstPage>
			<LastPage>80</LastPage>
			<ELocationID EIdType="pii">212610</ELocationID>
			
<ELocationID EIdType="doi">10.22034/jrenew.2025.212610</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>علی</FirstName>
					<LastName>خالقی بابایی</LastName>
<Affiliation>کارشناسی ارشد، معماری، دانشگاه گیلان، رشت، ایران</Affiliation>
<Identifier Source="ORCID">0009-0000-3055-6980</Identifier>

</Author>
<Author>
					<FirstName>اردلان</FirstName>
					<LastName>افلاکی</LastName>
<Affiliation>استادیار، معماری، دانشگاه گیلان، رشت، ایران</Affiliation>
<Identifier Source="ORCID">0000-0001-5489-0430</Identifier>

</Author>
<Author>
					<FirstName>معصومه</FirstName>
					<LastName>میرصفا</LastName>
<Affiliation>استادیار، معماری، دانشگاه دانمارک جنوبی، کپنهاگ، دانمارک</Affiliation>
<Identifier Source="ORCID">0000-0001-7725-818X</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>06</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		    <Abstract>High consumption of energy in commercial buildings due to public use at different hours leads to irreparable consequences, including damage to the environment. As an effective building component in radiation control, facade plays an important role in reducing energy consumption. Unfortunately, in recent years, attention to the aesthetic dimension of the building has caused the role of the facade and the use of up-to-date techniques in the field of building technology to be less investigated as an effective energy reducer. The current study, by using a double-shell facade instead of a single-shell facade or a combination of single-shell and two-shell facades in a commercial building in Karaj, investigates the role of using double-skin facades and combined facades in reducing heat and cold loss through walls. The study conducts library and documentary studies to conduct research background, and establishes simulation method using Design Builder software to measure the effectiveness of the mentioned technique in cold and dry climate. The results of the study show that the consumption of gas and electricity in the coldest and hottest months of the year in the combined facade compared to single skin facade is reduced by approximately 20% and 15%, respectively. On the other hand, due to the insignificant reduction of energy in the comparison of two-layer and combined facades, in order to reduce the costs of construction and execution in the building, the combined facade has a better justification in cold and dry climates.</Abstract>
			<OtherAbstract Language="FA">مصرف زیاد انرژی در ساختمان‌های تجاری به دلیل استفاده عموم در ساعات مختلف، تبعات جبران‌ناپذیری ازجمله آسیب به محیط‌زیست را به دنبال دارد. نما به‌عنوان یک ‌جز مؤثر ساختمان در کنترل تابش، نقش مهمی در کاهش مصرف انرژی دارد. متأسفانه در سال‌های اخیر توجه به بعد زیبایی‌شناختی بنا باعث شده که نقش‌نما و استفاده از راهکار‌های به‌روز در زمینه تکنولوژی ساختمان به‌عنوان کاهنده مؤثر انرژی کمتر موردبررسی قرار گیرد. مطالعه حاضر با استفاده از نمای دو‌پوسته به‌جای نمای تک‌پوسته و یا ترکیب تک‌پوسته و دو‌پوسته در ساختمان ‌تجاری در کرج، به نقش استفاده از نمای دو‌پوسته و ترکیبی در کاهش هدررفت سرما و گرما از طریق دیوارها می‌پردازد. این پژوهش ازلحاظ هدف از نوع توسعه‌ای-کاربردی می‌باشد و از روش تحقیق شبیه‌سازی برای سنجش میزان اثرگذاری راهکار‌ها در اقلیم سرد‌و‌خشک بهره می‌برد. همچنین از ابزار مطالعات کتابخانه‌ای و اسنادی برای انجام پیشینه تحقیق استفاده شده -است. نتایج مطالعه نشان می‌دهد که گاز و برق مصرفی در سردترین و گرم‌ترین ماه سال در نمای ترکیبی تک‌پوسته-دوپوسته نسبت به تک‌پوسته به ترتیب به میزان تقریبی 20% و 15% کاهش می‌یابد. از طرف دیگر، با توجه به کاهش نامحسوس انرژی در مقایسه نماهای دوپوسته و ترکیبی، جهت کاهش هزینه-های ساخت‌و‌اجرا در ساختمان، نمای ترکیبی در اقلیم سرد‌و‌خشک، توجیه‌پذیری بهتری دارد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نمای دوپوسته</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کاهش مصرف انرژی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تکنولوژی ساختمان</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مطالعات پارامتریک</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شبیه سازی انرژی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jrenew.ir/article_212610_705a72d922ecdc6a54d2eb28b8497fee.pdf</ArchiveCopySource>