<ArticleTitle>Multi-objective optimization of visual and thermal comfort in classrooms as a function of room dimensions and proportions (case study : secondary high schools in Tabriz city)</ArticleTitle>
<VernacularTitle>بهینه سازی چند متغیره آسایش بصری و حرارتی در کلاس‌های مدارس شهر تبریز با توجه به ابعاد و تناسبات فضا (نمونه موردی: دبیرستان‌های مقطع دوم متوسطه)</VernacularTitle>
			<FirstPage>90</FirstPage>
			<LastPage>99</LastPage>
			<ELocationID EIdType="pii">196246</ELocationID>
			
<ELocationID EIdType="doi">10.22034/jrenew.2024.196246</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>الهام</FirstName>
					<LastName>سلیقه</LastName>
<Affiliation>دانشکده معماری و شهرسازی، دانشگاه هنر اسلامی تبریز، تبریز، ایران</Affiliation>

</Author>
<Author>
					<FirstName>آیدا</FirstName>
					<LastName>ملکی</LastName>
<Affiliation>گروه معماری، دانشکده معماری و شهرسازی، دانشگاه هنر اسلامی تبریز</Affiliation>
<Identifier Source="ORCID">0000-0003-3490-3251</Identifier>

</Author>
<Author>
					<FirstName>یاسر</FirstName>
					<LastName>شهبازی</LastName>
<Affiliation>دانشکده معماری و شهرسازی، دانشگاه هنر اسلامی تبریز، تبریز، ایران.</Affiliation>

</Author>
<Author>
					<FirstName>عباس</FirstName>
					<LastName>غفاری</LastName>
<Affiliation>دانشکده معماری و شهرسازی، دانشگاه هنر اسلامی تبریز، تبریز، ایران.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>12</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		    <Abstract>The complexity of the design and the abundance of aspects that must be considered simultaneously by designers make it necessary to pay attention to different variables, which leads to the optimization of different functions. Other results of studies in this area are the identification of different variables. This study aims to investigate the effects of the dimensional variables and the ratio of area to volume of the classroom on the visual and thermal comfort of the users. For this purpose, the performance of the model in terms of the variables of and thermal comfort was investigated based on the weather data of Tabriz city using the simulator plugins Honeybee and Ladybug and the optimization plugin Octopus based on the evolutionary algorithm. The results of the survey show that the area-to-volume ratio of desired classrooms ranges from 1.16 to 1.69. The outcomes deemed optimal for the objectives of glare probability and daylight autonomy suggest that the most favorable solutions lie within the lower range of the surface area-to-volume ratio. Conversely, concerning comparative thermal comfort, the optimal solutions are found within the upper portion of the aforementioned range.</Abstract>
			<OtherAbstract Language="FA">روش بهینه سازی چند منظوره و استفاده از الگوریتم های بهینه سازی چند هدفه راهکاری برای تسهیل دستیابی همزمان به متغیرهای گوناگون در ساختمان است. پرداختن به عملکردهای مختلف در ساختمان ها و شناسایی متغیرهای متنوع از دیگر نتایج مطالعات این حوزه هستند. پژوهش حاضر به دنبال بررسی تاثیر متغیرهای ابعادی و نسبت سطح و حجم کلاس درس بر آسایش بصری و حرارتی کاربران است. مدل مورد بررسی در این مطالعه، کلاس درس مقطع دوم متوسطه در شهر تبریز می باشد. به این منظور عملکرد مدل در مورد متغیرهای کفایت نور روز، احتمال خیرگی و آسایش حرارتی با توجه به داده های آب و هوایی شهر تبریز با استفاده از پلاگین‌های شبیه ساز در بستر نرم افزار راینو گرس هاپر مطالعه گردیده است. نتایج پژوهش نسبت سطح به حجم کلاس های درسی مطلوب را بین بازه 1.16 تا 1.69 معرفی می نماید. بررسی جداگانه اهداف و پاسخ های برتر هر هدف بیانگر این موضوع هستند که در اهداف میزان خیرگی و کفایت نور روز نسبت سطح به حجم کمتر در بازه مذکور و در هدف مربوط به آسایش حرارتی تطبیقی نسبت سطح به حجم بالاتر در این بازه مطلوبتر بوده‌اند.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">بهینه‌سازی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آسایش حرارتی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کفایت نور روز</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">خیرگی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کلاس</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jrenew.ir/article_196246_9419a21d1ed58328b28a5b1f1ccca838.pdf</ArchiveCopySource>
</Article>
</ArticleSet>