<ArticleTitle>Modeling and technical-economic analysis of the combined cooling, heat &amp; power systems (CCHP) based on a gas engine for use in a greenhouse in Tehran</ArticleTitle>
<VernacularTitle>مدلسازی و تحلیل فنی - اقتصادی یک سیستم تولید همزمان برق، حرارت و برودت (CCHP) بر پایه موتور گازسوز جهت کاربرد برای یک گلخانه در شهر تهران</VernacularTitle>
			<FirstPage>77</FirstPage>
			<LastPage>89</LastPage>
			<ELocationID EIdType="pii">169784</ELocationID>
			
<ELocationID EIdType="doi">10.52547/jrenew.10.2.77</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>جاماسب</FirstName>
					<LastName>پیرکندی</LastName>
<Affiliation>دانشیار، مجتمع دانشگاهی هوافضا، دانشگاه صنعتی مالک اشتر، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>مرتضی</FirstName>
					<LastName>حسین پور</LastName>
<Affiliation>استادیار، گروه پژوهشی انرژی های تجدید پذیر، پژوهشگاه نیرو، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>شبنم</FirstName>
					<LastName>منصوری</LastName>
<Affiliation>کارشناس ارشد، گروه پژوهشی سیکل و مبدل های حرارتی، پژوهشگاه نیرو، تهران، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2022</Year>
					<Month>12</Month>
					<Day>02</Day>
				</PubDate>
			</History>
		<Abstract>Providing electrical, thermal and cooling energy in greenhouses is a very important issue. Due to the low efficiency of most of the conventional systems in greenhouses, the use of simultaneous production of electricity, heat and cooling (CCHP) systems has been highly considered in recent years. The main purpose of this article is the technical and economic feasibility of CCHP technology for use in a greenhouse in Tehran. In this research, a cucumber greenhouse with an area of 1 hectare, which consists of two structures of 0.5 hectare, has been analyzed and investigated. In order to analyze the technical-economic system used, calculations for four scenarios including the basic and conventional system, CCHP with absorption chiller and selling electricity to the grid, CCHP with absorption chiller and self-supply and CCHP with compression chiller and self-supply accepted. According to the results obtained for each scenario as well as the comparison of the selected scenarios, the greenhouse considered for the implementation of the CCHP system is not economical. The results of the research show that in case of using the CCHP system with absorption chiller and selling electricity to the grid, in order to make the system economical, the minimum rate of buying electricity from these units should be 3223 Rials per kilowatt hour. In the CCHP system with absorption chiller and self-supply, if the location of the greenhouse is such that 176 kilometers of transmission line is needed, this scenario becomes economical.</Abstract>
			<OtherAbstract Language="FA">تأمین انرژی الکتریکی، حرارتی و برودتی در گلخانه­ها موضوع بسیار مهمی است. با توجه به راندمان پایین بیشتر سیستم­های مرسوم در گلخانه­ها، استفاده از سیستم­های تولید همزمان برق، حرارت و برودت (CCHP) در سال­های اخیر به شدت مورد توجه قرار گرفته است. هدف عمده این مقاله امکان­سنجی فنی و اقتصادی تکنولوژی CCHP جهت کاربرد در یک گلخانه­ و برای شهر تهران است. در این پژوهش گلخانه خیاری با مساحت 1 هکتار که از دو سازه 5/0 هکتاری تشکیل شده، مورد تحلیل و بررسی قرار گرفته است. به منظور تحلیل فنی- اقتصادی سیستم استفاده شده، محاسبات برای چهار سناریو شامل سیستم پایه و مرسوم، CCHP با چیلر جذبی و فروش برق به شبکه، CCHP با چیلر جذبی و خودتأمین و CCHP با چیلر تراکمی و خودتأمین صورت پذیرفته است. با توجه به نتایج بدست آمده برای هر سناریو و همچنین مقایسه سناریوهای انتخابی، گلخانه در نظر گرفته شده جهت پیاده‌سازی سیستم CCHP اقتصادی نیست. نتایج تحقیق نشان می­دهد که در صورت استفاده از سیستم CCHP با چیلر جذبی و فروش برق به شبکه، جهت اقتصادی شدن سیستم حداقل نرخ خرید برق از این واحدها باید 3223 ریال به ازای هر کیلووات ساعت باشد. در سیستم CCHP با چیلر جذبی و خودتأمین، چنانچه موقعیت گلخانه به نحوی باشد که نیاز به 176 کیلومتر خط انتقال باشد این سناریو اقتصادی می‌گردد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">گلخانه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تحلیل فنی- اقتصادی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">سیستم تولید همزمان</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نرخ تورم</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آنالیز حساسیت</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jrenew.ir/article_169784_f068655138e3d1aaeec35523aac098df.pdf</ArchiveCopySource>
</Article>
</ArticleSet>